318984-753. 2347563, 3195827, HC21ZE117, K674, 10704, TJ318984-753, AP5634784, 318984753, 323435-730, 323435730, 323435-724, 323435724, 323435-701, 323435701, HC21ZE114, 321373-712, 321373712, HC21ZE114A, 321373-711, 321373711, 321373-710, 321373710, 321373-709, 321373709, 321373-708, 321373708, 321373-707, 321373707, 321373-706, 321373706, 321373-705, 321373705, 321373-704, 321373704, 321373-702, 321373702, 321373-701 & more!
- Quality you can Trust! All Snap Products are made with premium materials and are tested so they last.
- Compatible with the following HVAC brands: Carrier.
Wire Harnesses
This PRYSM inducer motor comes with extra wire harnesses to fit a variety of different models. Please note, no installation screws are included.
Instructions Included
Easy to follow step by step instructions are included in the box
Installation Instructions
Installation Instructions for 318984-753
- Disconnect electrical power supply to the appliance
- Remove the access panel to the HVAC System
- Remove motor from housing by removing all the screws holding it in place, typically, 3-4
- Pull motor out and unscrew wheel from motor shaft. (there is a gap in the wheel to reach). If you cannot get screw to budge stop here and buy the wheel that goes with it.
- If you cannot get the wheel to come off use a saw to cut the shaft from the old motor.
- Unscrew the 3 screws holding the motor to the plate plus ground wire
- Flip motor over remove 2 screws holding motor to second plate
- Take motor out and put new one in place and start screw the 2 plates back on
- Once motor is secured to the 2 plates attach the wheel to the shaft. Make sure you test that the wheel is tight and will not slip on shaft!
- Attach plastic wheel to back of motor and secure it in place with the metal clips. Hand spin wheel to make sure everything rotates smoothly with no wobble
- Install motor back into the HVAC unit attach cords to the 2 terminals and give it a test!